Heat Loss through front Cavity Wall


U-Value: 0.97 W/m2°K

The area of the wall is: 17.9 m2

The calculated degree hours are: 37,440 °K h

Using the units for U-Value W/m2 °K

m2 and °K cancel.

Product of the above figures.

0.97 x 17.9 x 37,440 = 650,071 Wh

@ 8p/kWh 650 kWh per annum